| 6 | 1101 | Robot Vacuum | 1 | Electricity 120V | Place lock and Tag on main disconnect in off position | Lock and Tag | Main electrical | Lockout | Stored energy electrical and hydraulic | Link to Picture | 2023-01-10 22:30:02 |
| 7 | 1101 | Robot Vacuum | 1 | Electricity | Identify -Types of energy, potential hazards and control devices. | | | | | Link to Picture | 2022-05-27 09:02:43 |
| 8 | 1101 | Robot Vacuum | 7 | Electricity | Test operating controls in the on position. (Be sure that no one can get hurt before testing | | | | | Link to Picture | 2022-05-27 09:23:44 |
| 9 | 1101 | Robot Vacuum | 10 | Electricity | Remove lockout devices only after equipment is fully assembled and all affected personnel have been notified | | | | | | 2022-05-27 10:29:58 |
| 10 | 1102 | Pallet Conveyor 1 | 5 | Electricity | Isolate energy sources | | | | | Link to Picture | 2022-05-27 10:37:18 |
| 11 | 1102 | Pallet Conveyor 1 | 10 | Electricity | Remove lockout devices only after equipment is fully assembled and all affected personnel have been notified.(each lockout device must be removed by the person that put it on) | | | | | Link to Picture | 2022-05-27 11:25:17 |
| 12 | 1104 | Pallet Conveyor 3 | 10 | Electricity | Remove lockout devices only after equipment is fully assembled and all affected personnel have been notified. (Each lockout device must be removed by the person that put it on) | | | | | Link to Picture | 2022-05-30 11:39:38 |
| 13 | 1105 | Pallet Conveyor 4 | 10 | Electricity | Remove lockout devices only after equipment is fully assembled and all affected personnel have been notified.(each lockout device must be removed by the person that put it on) | | | | | Link to Picture | 2022-05-27 12:43:24 |
| 14 | 1100 | Robot Palletizer | 10 | Electricity | Remove lockout devices only after equipment is fully assembled and all affected personnel have been notified. (Each lockout device must be removed by the person that put it on) | | | | | Link to Picture | 2022-05-27 12:56:51 |
| 15 | 1095 | Case Erector 0 | 10 | Electricity | Remove lockout devices only after equipment is fully assembled and all affected personnel have been notified.(each lockout device must be removed by the person that put it on) | | | | | Link to Picture | 2022-05-30 10:47:01 |
| 16 | 1096 | Case Erector 3 | 10 | Electricity | Remove lockout devices only after equipment is fully and all affected personnel have been notified. (Each lockout device must be removed by the person that put it on. | | | | | Link to Picture | 2022-05-27 13:44:58 |
| 17 | 1096 | Case Erector 3 | 6 | Electricity | Lockout all switches and energy controls in the off position | | | | | Link to Picture | 2022-05-30 12:15:07 |
| 19 | 1112 | Case Taper 3 | -1 | Electricity 120V | Lock out main panel | Lock | Main Switch on left side | Lock the switch | Press green start button | Link to Picture | 2022-05-30 22:59:40 |
| 20 | 1096 | Case Erector 3 | 1 | Electricity | Lock out main panel | | | | | Link to Picture | 2022-05-30 12:47:45 |
| 21 | 1070 | Seasoner 4 | 1 | Electricity | Lock out electrical main | | | | | Link to Picture | 2022-05-30 13:12:38 |
| 23 | 1109 | Forklift 4 | 1 | Other | | Cable lockbox | Battery | Lockout | Stored energy electrical and hydraulic | Link to Picture | 2022-05-31 08:31:08 |
| 24 | 1102 | Pallet Conveyor 1 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lockout | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 07:43:22 |
| 25 | 1103 | Pallet Conveyor 2 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lockout | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 07:44:40 |
| 26 | 1104 | Pallet Conveyor 3 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lockout | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 07:46:04 |
| 27 | 1105 | Pallet Conveyor 4 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lockout | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 07:47:03 |
| 28 | 1100 | Robot Palletizer | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lockout | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 07:49:54 |
| 29 | 1096 | Case Erector 3 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 08:24:39 |
| 30 | 1095 | Case Erector 0 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 08:25:47 |
| 31 | 1108 | Forklift 3 | 1 | Electricity 120V | | Cable lockbox | Battery | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 08:30:38 |
| 32 | 1107 | Forklift 2 | 1 | Electricity 120V | | Cable lockbox | Battery | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 08:35:28 |
| 33 | 1106 | Forklift 1 | 1 | Electricity 120V | | Cable lockbox | Battery | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 09:03:10 |
| 34 | 1113 | Case Taper 0 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 09:10:33 |
| 35 | 1111 | Case Taper 1 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 09:24:34 |
| 36 | 1114 | Case Taper 2 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 09:25:12 |
| 37 | 1112 | Case Taper 3 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 09:26:11 |
| 38 | 1053 | Vibratory Platform 1 (East) | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 09:28:50 |
| 39 | 1054 | Vibratory Platform 2 (West) | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 09:29:48 |
| 40 | 1055 | Vibratory Platform 3 (East) | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 09:30:40 |
| 41 | 1056 | Vibratory Platform 4 (West) | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 09:35:16 |
| 42 | 1057 | Vibratory Platform 5 (East) | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | | 2022-06-13 09:35:46 |
| 43 | 1058 | Vibratory Platform 6 (West) | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 09:36:48 |
| 44 | 1067 | Seasoner 1 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 09:38:26 |
| 45 | 1068 | Seasoner 2 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 09:39:25 |
| 46 | 1069 | Seasoner 3 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 10:10:03 |
| 47 | 1070 | Seasoner 4 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 10:10:47 |
| 48 | 1071 | Tumbler (Drum) 1 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 10:11:43 |
| 49 | 1072 | Tumbler (Drum) 2 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 10:13:03 |
| 50 | 1073 | Tumbler (Drum) 3 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 10:14:42 |
| 51 | 1074 | Tumbler (Drum) 4 | 1 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-06-13 10:15:35 |
| 52 | 1115 | Case Taper 4 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 09:05:19 |
| 53 | 1088 | Bag Conveyor 1 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 09:14:34 |
| 54 | 1089 | Bag Conveyor 2 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 09:18:19 |
| 55 | 1090 | Bag Conveyor 3 | 5 | Electricity 120V | | Lock and Tag | Electrical cable | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 09:20:23 |
| 56 | 1097 | Case Conveyors 2 | 5 | Electricity 120V | | Lock and Tag | Electrical cable | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 11:26:29 |
| 57 | 1098 | Case Conveyors 3 | 5 | Electricity 120V | | Lock and Tag | Electrical cable | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 11:27:33 |
| 58 | 1050 | Incline to Platform - 1 (Industrial) | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 11:38:06 |
| 59 | 1051 | Conveyor - Incline to Platform - 2 (Kettle) | required | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 11:49:14 |
| 60 | 1052 | Platform System | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 11:54:00 |
| 61 | 1075 | Scale 1 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 11:58:54 |
| 62 | 1076 | Scale 2 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 11:59:32 |
| 63 | 1077 | Scale 3 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:00:08 |
| 64 | 1067 | Seasoner 1 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:00:51 |
| 65 | 1068 | Seasoner 2 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:01:46 |
| 66 | 1069 | Seasoner 3 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:02:28 |
| 67 | 1035 | Vibratory Cross Conveyor - Industrial | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:05:17 |
| 68 | 1035 | Vibratory Cross Conveyor - Industrial | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:24:48 |
| 69 | 1059 | Even Flow 1 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:25:54 |
| 70 | 1060 | Even Flow 2 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:26:49 |
| 71 | 1060 | Even Flow 2 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:32:35 |
| 72 | 1061 | Even Flow 3 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:33:26 |
| 73 | 1062 | Even Flow 4 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:34:22 |
| 74 | 1063 | Mass Flow 1 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:35:46 |
| 75 | 1064 | Mass Flow 2 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:36:39 |
| 76 | 1065 | Mass Flow 3 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:37:27 |
| 77 | 1066 | Mass Flow 4 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:38:33 |
| 78 | 1082 | Metal Detector 0 (bulk) | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:39:25 |
| 79 | 1078 | Metal Detector 1 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:40:45 |
| 80 | 1079 | Metal Detector 2 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:41:29 |
| 81 | 1080 | Metal Detector 3 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:42:57 |
| 82 | 1081 | Metal Detector 4 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:43:51 |
| 83 | 1085 | Packager 3 | 5 | Electricity 120V | | Lock and Tag | Main electrical | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 12:51:19 |
| 84 | 1084 | Packager 2 | 5 | Electricity | Lock out main power, pneumatic will be disconnected without power. | Lock and Tag | Main electrical | Lock | Stored energy electrical and pneumatic | Link to Picture | 2022-07-20 12:52:45 |
| 85 | 1091 | Turn Table 1 | 5 | Electricity 120V | | Lock and Tag | Electrical cable | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 13:05:38 |
| 86 | 1092 | Turn Table 2 | 5 | Electricity 120V | | Lock and Tag | Electrical cable | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 13:06:47 |
| 87 | 1093 | Turn Table 3 | 5 | Electricity 120V | | Lock and Tag | Electrical cable | Lock | Stored energy electrical and hydraulic | Link to Picture | 2022-07-20 13:07:53 |
| 89 | 1021 | Slicer - 1-2 (A-B) | Step 1 | Electricity 220V | | LOTO pad lock | Power disconnect behind slicer | Lock and tag out switch | No power | Link to Picture | 2023-01-10 12:05:09 |
| 90 | 1022 | Slicer - 3-4 (C-D) | Step 1 | Electricity 220V | | LOTO pad lock | Left side of slicer unit when standing behind the unit | Lock and tag out switch | No power | Link to Picture | 2023-01-09 14:37:34 |
| 91 | 1023 | Slicer - 5-6 (E-F) | Step 1 | Electricity 220V | | LOTO pad lock | Right side of slicer unit when standing behind slicer unit | Lock and tag out switch | No power | Link to Picture | 2023-01-09 14:42:09 |
| 92 | 1083 | Packager 1 | Step 1 | Electricity 120V | | LOTO pad lock | Main switch | Lock and tag out switch | No power | Link to Picture | 2023-01-10 22:19:43 |
| 93 | 1025 | Pivot Belt - 1-2 (A-B) | Step 1 | Electricity 220V | | LOTO pad lock | Power disconnect behind slicer | Lock and tag out switch | No power | | 2023-01-24 13:59:26 |
| 94 | 1025 | Pivot Belt - 1-2 (A-B) | Step 1 | Electricity 220V | | LOTO pad lock | Power disconnect behind slicer | Lock and tag out switch | No power | Link to Picture | 2023-01-24 14:01:27 |
| 95 | 1086 | Bag Tester 2 | Step 1 | Electricity 220V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-25 11:19:37 |
| 96 | 1087 | Bag Tester 3 | Step 1 | Electricity 220V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-25 11:19:50 |
| 97 | 1048 | Buffer 2 (Kettle) | Step 1 | Electricity 220V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-25 11:20:06 |
| 98 | 1042 | Optical Sorter Lg - Kettle | Step 1 | Electricity 480V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-25 11:22:10 |
| 99 | 1057 | Vibratory Platform 5 (East) | Step 1 | Electricity 220V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-25 11:26:12 |
| 100 | 1049 | Buffer 3 (Bulk) | Step 1 | Electricity 220V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-25 11:28:36 |
| 101 | 1046 | Conveyor - Incline to Buffer - Kettle | Step 1 | Electricity 220V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-25 11:30:27 |
| 102 | 1014 | Conveyor - Potato Overhead Belt | Step 1 | Electricity 480V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-25 11:32:00 |
| 103 | 1011 | Conveyor - Inspection Belt | Step 1 | Electricity 480V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-25 11:33:28 |
| 104 | 1005 | Potato Transport 1 | Step 1 | Electricity 480V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-25 11:35:01 |
| 105 | 1006 | Potato Transport 2 | Step 1 | Electricity 480V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-25 11:35:36 |
| 106 | 1007 | Potato Transport 3 | Step 1 | Electricity 480V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-25 11:36:06 |
| 107 | 1009 | Vertical Auger | Step 1 | Electricity 480V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-25 11:37:36 |
| 108 | 1043 | Conveyor - Vibratory Cross Conveyor - Kettle | Step 1 | Electricity 480V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-25 11:39:20 |
| 109 | 1029 | Fryer - Kettle 1 (A) | Step 1 | Electricity 220V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-31 11:07:37 |
| 110 | 1030 | Fryer - Kettle 2 (B) | Step 1 | Electricity 220V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-31 11:08:22 |
| 111 | 1031 | Fryer - Kettle 3 (C) | Step 1 | Electricity 220V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-31 11:09:45 |
| 112 | 1032 | Fryer - Kettle 4 (D) | Step 1 | Electricity 220V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-31 11:10:23 |
| 113 | 1033 | Fryer - Kettle 5 (E) | Step 1 | Electricity 220V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-31 11:13:45 |
| 114 | 1034 | Fryer - Kettle 6 (F) | Step 1 | Electricity 220V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-31 11:14:28 |
| 115 | 1029 | Fryer - Kettle 1 (A) | Step 2 | Natural Gas | | Valve Lock out with lock out pad lock | Natural gas pipe ball valve | Lock and tag out | No Gas | Link to Picture | 2023-01-31 11:17:34 |
| 116 | 1030 | Fryer - Kettle 2 (B) | Step 2 | Natural Gas | | Valve Lock out with lock out pad lock | Natural gas pipe ball valve | Lock and tag out | No Gas | Link to Picture | 2023-01-31 11:18:41 |
| 117 | 1031 | Fryer - Kettle 3 (C) | Step 2 | Natural Gas | | Valve Lock out with lock out pad lock | Natural gas pipe ball valve | Lock and tag out | No Gas | Link to Picture | 2023-01-31 11:19:55 |
| 118 | 1032 | Fryer - Kettle 4 (D) | Step 2 | Natural Gas | | Valve Lock out with lock out pad lock | Natural gas pipe ball valve | Lock and tag out | No Gas | Link to Picture | 2023-01-31 11:20:50 |
| 119 | 1033 | Fryer - Kettle 5 (E) | Step 2 | Natural Gas | | Valve Lock out with lock out pad lock | Natural gas pipe ball valve | Lock and tag out | No Gas | Link to Picture | 2023-01-31 11:24:42 |
| 120 | 1034 | Fryer - Kettle 6 (F) | Step 2 | Natural Gas | | Valve Lock out with lock out pad lock | Natural gas pipe ball valve | Lock and tag out | No Gas | Link to Picture | 2023-01-31 11:25:40 |
| 121 | 1040 | Optical Sorter Sm - Industrial | Step 1 | Electricity 480V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-31 11:34:56 |
| 122 | 1025 | Pivot Belt - 1-2 (A-B) | Step 1 | Electricity 220V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-31 11:36:14 |
| 123 | 1026 | Pivot Belt - 3-4 (C-D) | Step 1 | Electricity 220V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-31 11:40:53 |
| 124 | 1027 | Pivot Belt - 5-6 (E-F) | Step 1 | Electricity 220V | | Lock out pad lock | Main electrical switch | Lock and tag out switch | No power | Link to Picture | 2023-01-31 11:42:17 |
| 125 | 1123 | Pressure Washer - Hot Steam | Step 1 | Electricity 120V | | Electrical plug lock out cover with lock out padlock | Electrical plug | Lock and tag out | No power | Link to Picture | 2023-01-31 13:33:54 |
| 126 | 1029 | Fryer - Kettle 1 (A) | Step 3 | Vegetable Oil | | Gate valve lock out with lock out padlock | Main oil pipe | Lock and tag out | No oil flow | Link to Picture | 2023-02-14 11:04:13 |
| 127 | 1030 | Fryer - Kettle 2 (B) | Step 3 | Vegetable Oil | | Gate valve lock out with lock out padlock | Main oil pipe | Lock and tag out | No oil flow | Link to Picture | 2023-02-14 11:05:50 |
| 128 | 1031 | Fryer - Kettle 3 (C) | Step 3 | Vegetable Oil | | Gate valve lock out with lock out padlock | Main oil pipe | Lock and tag out | No oil flow | Link to Picture | 2023-02-14 11:07:06 |
| 129 | 1032 | Fryer - Kettle 4 (D) | Step 3 | Vegetable Oil | | Gate valve lock out with lock out padlock | Main oil pipe | Lock and tag out | No oil flow | Link to Picture | 2023-02-14 11:08:41 |
| 130 | 1033 | Fryer - Kettle 5 (E) | Step 3 | Vegetable Oil | | Gate valve lock out with lock out padlock | Main oil pipe | Lock and tag out | No oil flow | Link to Picture | 2023-02-14 11:09:58 |
| 131 | 1034 | Fryer - Kettle 6 (F) | Step 3 | Vegetable Oil | | Gate valve lock out with lock out padlock | Main oil pipe | Lock and tag out | No oil flow | Link to Picture | 2023-02-14 11:11:04 |
| 132 | | | | | | | | | | | 2024-06-28 21:11:02 |
| 133 | | | | | | | | | | | 2025-04-27 12:16:49 |
| 134 | | | | | | | | | | | 2025-05-24 02:28:59 |
| 135 | | | | | | | | | | | 2025-08-23 07:57:13 |
| 136 | | | | | | | | | | | 2025-09-12 22:51:25 |
| 137 | | | | | | | | | | | 2025-12-16 07:56:20 |
| 138 | | | | | | | | | | | 2026-01-01 12:00:18 |